Pulsar Model 22 doseBadge Dosimeter

Pulsar Model 22 doseBadge Dosimeter:

The Pulsar Model 22 doseBadgesystem can be rented as part of a complete noise measurement kit, containing all that is required to carry out a personal noise monitoring.

Pulsar Model 22 doseBadgesystem kit contain:

  • Pulsar Model 22 doseBadge
  • Pulsar Model 22RdoseBadge readercum Calibrator
  • Mount holder
  • Metal Carry box
  • Power Supply
  • Charger Unit
  • AA batteries
  • Manufacturer calibration certificates for Reader and doseBadges
  • User manual
  • Reporting software 
  • USB download cable

Applications

  • The Model 22 doseBadge systems are ideal for most applications as the preferredmethodof calculating personal daily noise exposures to ensure compliance with InternationalSafety Legislation.
  • It is especially suitable for applications where workers are regularly moving from locationto location, working with moving machinery, in difficult to reach areas, vehicle cabins,shift work or with unpredictable work patterns.
  • Typical industries include: Manufacturing, Construction, Chemical, Mining,Transportation, Fire and Police, Highway Maintenance, Food, Entertainment and alsoEducational Establishments.
  • MOM Noise Report Part-G : Personal noise exposure compliance

Standards

Model 22 doseBadge:

  • IEC 61252:1993 Personal Sound Exposure Meters
  • ANSI S1.25:1991 Personal Noise Dosemeters

Model 22-R Reader Unit:

  • Internal Acoustic Calibrator to IEC 60942:2001 Class 2

Technical Specifications

  • Measurement Range (dBA): 70 - 130dB RMS
  • Measurement Range (dBC): 120 - 140dB Peak
  • Frequency Types (Weighting): A, C
  • Memory: Up to 93 measurements of 8 hours duration
  • Weight: 45 grams
  • Battery Type: Rechargeable NiMH battery
  • International Standards: IEC 61252:1993, IEC 60942:2001 Class 2, ANSI S1.25:1991
  • Exchange rate (Q) 3dB, 4dB, 5dB
  • Criterion Level 80dB, 85dB, 87dB, 90dB
  • Criterion Time 8, 12, 16, 18 hours
  • Threshold None, 80dB, 85dB, 90dB
  • Time Weighing None or slow

Features

  • Ideal system for compliant assessment of workers’ industrial noise exposures
  • Small compact and lightweight, weighing only 45grams
  • Rugged and durable aluminium housing
  • Cable-free operation
  • Programmable with compliance for almost all world wide safety regulations
  • Infra-red reader with internal acoustic calibrator
  • Simple reporting via dBLink3 or Analyzer Plus software programs